Sign In | Join Free | My xpandrally.com
China Hebei Kaixiang Electrical Technology Co., Ltd logo
Hebei Kaixiang Electrical Technology Co., Ltd
Active Member

8 Years

Home > 3 Phase Load Bank >

RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering

Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now

RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering

  • 1
  • 2

Brand Name : Kaixiang

Model Number : AC400-5000kW

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 35 Sets per Month

Delivery Time : Within 30 working days

Packaging Details : Container for Load bank

Power factor : 0.8

Max Protection Grade : IP54

Dimensions : About 7000mm*2350mm*2591mm(L×W×H

Frequency : 50 HZ

Colour : Grey RAL7035

Communication Interface : RS485、RS232

Contact Now

AC400-5000kW 3 Phase Load Bank Resistive In Blue Colour And High Performance

Product description

(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-5000kW Resistive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.

(2) The system consists of 1 sets of 5000kW Resistive load bank. The resistive power is 5000kW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

Technical Parameter

System Parameter
Rating voltage/frequency 400V 3 phase 4 line,line voltage: 400V, phase voltage: 230V, 50Hz
Max Load Power Resistive Load: 5000kW
Load Resolution

Resistive Load: 29steps,

10kW,20kW,20kW,50kW,100kW,

200kW,200kW,200kW,200kW,200kW,200KW,200kW,200kW,200kW,

200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,

200kW,200kW,200kW,200kW,200kW,200kW

Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External 380V 3 phase 4 line, line voltage: 380V, phase voltage: 220V, 50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 7000mm*2350mm*2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor (self-developing)
Data Processing Software (self-developing)
Product Advantage

(1) Communication Mode: using photoelectric isolated RS485 communication serial port connect to PC, and with great anti-interference performance to make system control stable. Through converts like USB or RS232 realize communication protocol conversion.

(2) Load Mode: steady-state load (manual load, preset load and automatic load) and transient state load (instant load and instant unload).

(3) Manual Load: input power and power factor, and load according to the preset value.

(4) Preset Load: input generator related parameters, then choose the preset proportion from 0% 25%, 50%, 75%, 100% or other available order and calculate the power value automatically and realize rapid load.

(5) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. Pause at any time or start to next stage in the load process.

(6) Parallel Test: several load banks work in parallel, the parallel test via software. Parameters of each set can be displayed in each meter and total parameter values can be displayed and recorded.

Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test

RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering


Product Tags:

high voltage load bank

      

load bank testing of generator sets

      
Wholesale RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering from china suppliers

RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hebei Kaixiang Electrical Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)